Residual Current Breaker with Over-current Protection (RCBO)

Description
1. The unit combines the over current protection of the "Memguard" MCB with an electronic RCD capable of high sensitivity operation with special fail-safe features.
2. It is suitable for installation in "MEMGUARD" SPN type A or type B boards operating on single phase 240V system.
3. It is used for single-phase protection against overload, short circuit and earth leakage currents.

Over Current Protection
1. Over current protection to circuit conductors is offered by thermal and magnetic tripping elements is the line side, equivalent to the "MEMGUARD" MCB and is available in both M3 & M6 versions.
2. Operating characteristics on over current (the time/current curves) are as for the "MEMGUARD" standard MCB.
3. It meets the requirements of BSEN60947-2 for miniature circuit breakers. Short circuit requirements comply with BS4293.

Earth Fault Protection
The RCD elements of the device offer core-balance detection of the difference between line and neutral currents and amplification for high sensitivity.

Operation of the Test Button
This check is made after installation with all shields and covers in place, and requires the MCB/RCD and the main supply switched on.
Pressing the button marked "T" on the MCB/RCD applies a simulated earth-fault to the MCB/RCD which should trip instantly.
This should be frequently checked, at least quarterly. If the MCB/RCD fails to trip seek expert advice.

Note
Operation of the test device checks only the correct functioning of the MCB/RCD at a higher current than the rated tripping level. The integrity of the earthing system is not checked.

Installation
1. Fit MCB/RCD unit as required into "MEMGUARD" consumer/distribution board.
2. Connect the BLACK flying neutral supply lead to the Neutral supply terminal block.
3. The LOAD connections are made to the outgoing terminals of the unit marked 'L"LOAD and "load.
4. High voltage insulation testers must not be used with the unit in circuit. To carry out HV tests disconnect load side cables from MCB/RCD unit and test circuit as normal.

We are one of major residual current breaker manufacturers in China. Firstly, thanks very much for visiting our website. We have 30 years experience in manufacturing electric switches and circuit breakers. Our superior micro switch, miniature circuit breaker, contactor, thermal relay, etc. are sold at economical prices. Welcome you to order our products!

Other Products
    1. EMC Cable Gland Solely cut jacket layer and shielding layer of EMC cable gland help save installation time.
      Reliable greater shielding surface: a better contact...
    1. Distribution BoxIt is made of standard cold-rolled steel and adopts powder-coating technique to process the crust.
      This beautiful...
    1. Wall Mount Enclosure Enclosure & Door: sheet steel 1.2mm till size CRN6 820 then 1.5mm
      Mounting plate: sheet steel 1.5mm till size CRN6 ...
    1. Battery Power ToolCu compression cable lugs and compression joints
      Crimping range: 16-3002
      Aluminum compression cable lugs and ...